    Hyde Park Towers, Porchester Terrace, London W2


    Cool You supplied air conditioning for apartments in Hyde Park Towers, which overlooks Hyde Park with our exclusive fully internal systems.

    We provided air conditioning solutions for the apartments in Hyde Park Towers. A modern building in the Bayswater conservation area in the City of Westminster. The unique challenge we faced was overcoming strict regulations that prohibited the installation of traditional external condenser units or drilling holes in the building’s exterior.

    To meet the client’s needs, we installed a cutting-edge internal condenser air conditioning system that required no alterations to the building’s external structure. This allowed us to provide air conditioning for three bedrooms and the living area as part of a complete refurbishment project.

    Emphasis on energy efficiency

    With a strong emphasis on energy efficiency, we installed small water-cooled condensers in each of the three en-suite bathrooms. We paired them with energy-efficient, quiet DC inverter high-wall units in each bedroom. A more powerful condenser was strategically placed in the kitchen to supply a discreet, hidden ducted unit for the main living room, ensuring a comfortable environment with minimal energy consumption.

    Our dedicated engineers worked closely with the client’s contractors to integrate the air conditioning system into the apartments seamlessly. Connecting the refrigerant pipework between the condenser and the room units before the false ceilings were installed ensured a smooth and visually unobtrusive installation process.

    No planning permission needed

    Notably, our solution did not require planning permission, showcasing our ability to provide effective air conditioning solutions within strict regulatory constraints. Our commitment to teamwork and client satisfaction was evident throughout the project, and we take pride in delivering a tailored, energy-efficient air conditioning system for the apartments in Hyde Park Towers.

    For these projects, we installed:

    Living room
    1 x 7kwwater cooled DC Inverter condenser fitted within a cupboard in the adjoining kitchen
    to serve: 1 x 7kw (24,000 Btu) DC Inverter Ducted unit

    Master bedroom
    1 x 2.6kw water cooled DC Inverter condenser fitted within a cupboard in en suite bathroom design,
    to serve: 1 x 2.6kw (9,000 Btu) DC Inverter high wall unit
    Bedroom 2
    1 x 2.6kw water cooled DC Inverter condenser fitted within a cupboard in en suite bathroom design,
    to serve: 1 x 2.6kw (9,000 Btu) DC Inverter high wall unit
    Bedroom 3
    1 x 2.6kw water cooled DC Inverter condenser fitted within a cupboard in en suite bathroom design,
    to serve: 1 x 2.6kw (9,000 Btu) DC Inverter